Vacuum filter station Mucus Filter is designed for flow filtration of liquids, including biological liquid substances.

Device for vacuum filtration and microfiltration of biological fluids Mucus Filter I by Bulova for filtering mucus of mollusks and other biological fluids under pressure, filtration range 0.2-100 µm. With the possibility of washing the filter elements.
For capsule type filter elements 5×2.5 inches.
With vacuum pump.
Weight: 22 キログラム. Working dimensions (without vacuum pump), mm: 540 x 470 x 1100.
Replacement filters are not included.
To filter snail mucus, it is recommended to use membrane-type capsule filter cartridges with gradual liquid filtration from 1 µm to 0.45 µm, and up to 0.2 µm if necessary.
Model I : Steel grade AISI 316, AISI 430 費用:
€2200 produced by Bulova in Ukraine
€2900 produced in the Czech Republic under Bulova license, CE certificate of conformity

HSコード: 8421 29 20 00

Filtering snail mucus Cartuchos de filtro de cápsula de repuesto para la filtración de moco de caracol Baba de caracol después de la filtración


Microfiltration station “Mucus Filter III”

Device for vacuum filtration of biological fluids “Mucus Filter III (IV) from Bulova company for filtering mucus from mollusks and other biological fluids under pressure, filtration range 0.2-100 microns. With the possibility of flushing the filter elements.
For 10×2.5 in. Flow-through filter elements.
With vacuum pump.
Weight: 25 キログラム. Working size, excluding the vacuum pump, mm: 540 X 470 X 1100
Replacement Filters are not included.

Model III : Steel grade AISI 316, AISI 430 費用:
€2500 produced by Bulova in Ukraine
€3200 produced in the Czech Republic under Bulova license, CE certificate of conformity
Model IV : Steel grade AISI 316, AISI 430 費用:
€2400 produced by Bulova in Ukraine
€3100 produced in the Czech Republic under Bulova license, CE certificate of conformity
HSコード: 8421 29 20 00

真空フィルターステーション Mucus Filter

Operating instructions

  1. Assemble the support structure by connecting the three parts of the support tripod (ある+B+C) together and securing them with bolts.
  2. Attach the hanging flasks (1 そして 2) to the vertical support post, flask 3 to the horizontal support post, securely fastening them to the brackets with bolted connections.
  3. Connect flasks 1, 2 そして 3 to each other using pipelines in the “Filtration” mode, as shown in the diagram.
  4. Fill the vacuum pump with vacuum motor oil.
  5. Install the moisture trap (4) and connect it to the flask with the finished product (3) and the vacuum pump.
  6. Install a replaceable filter cartridge of the required size into the filter holder flask (2).
  7. Make sure that the necessary taps (2.2, 2.4,) are open for the device to operate in theFiltrationmode.
  8. To check the tightness of the device, turn on the vacuum pump and close valve 2.2, if a vacuum is created in the system, then when opening valve 2.2 you will hear the sound of air intake.
  9. Your vacuum filtration station is ready to work!
  10. Pour the liquid to be filtered into the raw material flask (1)
  11. Turn on the vacuum pump.
  12. If you need UV radiation, turn on the UV lamp. Be careful with UV radiation, it is not safe!
  13. The filtration process is still in progress, the filtered product will flow into the lower flask for finished products (3).
  14. Make sure that the level of the filtered liquid in the lower flask (3) does not exceed 1/3 of the volume (there is a level on the window glass).
  15. Make sure that the filtered liquid does not enter the moisture trap (4). If liquid enters the moisture trap (4), stop the filtration process by turning off the vacuum pump and drain the liquid from the moisture trap.
  16. To drain the finished product, use tap 3.1

Not every snail slime is subject to filtration, much less microfiltration. Any filtration removes (filters out) useful elements from the product, 例えば, the Bulova company does not recommend filtering snail slime for the production of lyophilized snail slime.

Not every snail slime is subject to filtration, much less microfiltration

Microfiltration (0.2 µm size) is a conditionally sterile filtration. The membrane type filter cartridge cell, 0.2 microns in size, retains bacteria and microorganisms. But this is not always advisable for live products, such as snail mucus, when it is necessary to preserve the beneficial bactericidal microflora.

Replacement filter cartridges.
Filtration is a gradual and multi-stage process: from a larger filter cell size to a smaller one.

The multi-stage nature and size of the filter cartridge used depend on the density and specific gravity of the filtered product, the quantity and size of suspended particles in it, which are subject to filtration. Replacement filter cartridges can be of two types: for deep and surface filtration. Pleated glass fiber deep filtration filters and pleated polypropylene deep filtration filters are used for filtration of biological fluids and surface filtration membrane filters are thinner and are used for sterile filtration in medicine, They are also suitable for microfiltration of snail mucus.

Replacement filter cartridges are best selected empirically to filter your product.
Our company cannot select a filter cartridge type for you. Depth filters: fiberglass or polypropylene or surface filtration membrane?

例えば, to filter snail mucus, you can use filter cartridges from 10 µm to 0.2 µm (10, 5, 1, 0.5, 0.2 µm). Gradually re-filtering the product from larger to smaller sizes. By default, corrugated polypropylene replacement cartridges for deep filtration are offered, they are the most universal. Thinner filter cartridges should be ordered separately or purchased independently.

Replaceable filter element 費用, €
01 Filter cartridge 10”x2.5” , flow-through type, deep filtration, corrugated (PP) 0.2 µ 123
02 Filter cartridge 10”x2.5”, flow-through type, deep filtration, corrugated (PP) 1.0 µ 48
03 Filter cartridge 5”, capsule type, pleated and membrane (IPP) 1.0 µ 80
04 Filter cartridge 5”, capsule type, membrane (PES) 0.45 µ 111
05 Filter cartridge 5”, capsule type, membrane (PES) 0.2 µ 123

HSコード: 8421 99 90 00


Attention!
How to prepare a membrane filter cartridge for use.
A membrane filter is made of a synthetic semipermeable membrane (material: polyamide, polyester, or polysulfone).
To filter substances, the membrane must be pre-soaked !
1) Fill the membrane filter with distilled or demineralized water until it is full;
2) Leave the membrane filter filled with water for 20-30 minutes;
3) Completely drain the water from the membrane filter;
4) Install the membrane filter cartridge (through-type) into the filter holder, and the membrane filter cartridge (capsule type) into the clamp adapters, securing them with clamps, then connect them to the filter device pipeline.
5) You can begin the filtration process.

Typically, filtration proceeds from the largest filtration cell to the smallest. 例えば, first use a 5-micron filter cartridge, then a 1-micron filter cartridge, then a 0.45-micron filter cartridge or a 0.2-micron filter cartridge (if necessary).


Washing (for membrane filters only).
Membrane filters are washable and reusable.
1) Wash the filtration system, including all sections and pipelines without replaceable filter cartridges.
2) To wash the replaceable filter cartridges, use distilled or demineralized water!
3) Pour distilled or demineralized water (rinse water) into the upper liquid tank.
Install the replaceable filter cartridge in the normal filtration mode.
Turn on the unit and run the rinse water through the replaceable filter cartridge (as with filtration).
4) Reinstall the replacement filter cartridge in reverse flow filtration mode:
For a flow-through filter, reconnect the filter holder hoses in the reverse flow direction;
For a capsule filter, flip the filter cartridge over and reconnect the hoses in the reverse direction;
Turn on the device and repeat the flushing procedure. The return flow pressure must not exceed 1 bar.
5) If necessary, you can disinfect the replaceable filter cartridge; repeat the procedure with a non-alcohol, non-chlorine-containing disinfectant solution.
6) Drain all water or disinfectant solution from the replaceable filter cartridge, and after flushing is complete, pass air through the filtration system and replaceable filter cartridge.
7) Store the replacement filter cartridge dry in a dry place.

Tags: snail slime filtration, snail slime microfiltration, replacement filter cartridge cleaning process, Mucus Filter vacuum microfiltration station